Is This In Your Water?
ZIP 21157 · Westminster, MD · EPA MD0060015

City Of Westminster: water report for ZIP 21157

6 community water systems serve or are based in ZIP 21157. Showing City Of Westminster, the largest by reported population served. The other systems are summarized below.

System name
City Of Westminster
EPA PWS ID
MD0060015
Location
Westminster, MD
Population served
35,256
Water source
Surface water
Primary EPA source
EPA ECHO record for MD0060015

Make sure this is the system tied to your address before using these results to make a decision about your own water. A ZIP code is not a street address.

EPA lab monitoring (UCMR 5)

EPA UCMR 5 monitoring (Jan. 2023–Sept. 2025) detected 8 of the 30 monitored chemicals in this system's samples. Highest reported PFOA result: 12.4 ppt.

ChemicalHighest resultEPA legal limit (MCL)EPA health goal (MCLG)
PFOA
perfluorooctanoic acid
12.4 ppt4 ppt0
PFOS
perfluorooctanesulfonic acid
6.9 ppt4 ppt0
PFHxS
perfluorohexanesulfonic acid
4.2 ppt10 ppt10 ppt
PFPeA
perfluoropentanoic acid
66.7 pptNo federal MCL—
PFHxA
perfluorohexanoic acid
24.6 pptNo federal MCL—
PFBA
perfluorobutanoic acid
20.1 pptNo federal MCL—
PFBS
perfluorobutanesulfonic acid
8.6 pptNo federal MCL—
PFHpA
perfluoroheptanoic acid
8.1 pptNo federal MCL—

UCMR 5 results are monitoring data, not a compliance determination. PFAS compliance is governed by separate EPA drinking-water rules. Some PFAS rule changes are proposed for 2026 — see what's proposed.

Lead at customer taps

Lead at sampled customer taps, 90th percentile (Jan. 2022–Dec. 2024): 0 ppb. EPA's current action level is 15 ppb; its health goal (MCLG) is 0.

Lead is regulated with an action level rather than a standard MCL. EPA's lead action level is 15 ppb today; the Lead and Copper Rule Improvements lower it to 10 ppb starting Nov. 1, 2027.

Violations on the federal record

The EPA record shows 9 violations, 4 health-based.

TypeRule / contaminantSince
Record · missed required testing or reportingLead & Copper Rule2009
Record · missed required testing or reportingLead & Copper Rule2013
Health-based · exceeded a contaminant limitTotal Trihalomethanes (TTHM)2017
Health-based · exceeded a contaminant limitTotal Trihalomethanes (TTHM)2017
Health-based · exceeded a contaminant limitTotal Trihalomethanes (TTHM)2018
Health-based · exceeded a contaminant limitTotal Trihalomethanes (TTHM)2018
Record · missed required testing or reporting—2019
Record · missed required testing or reporting—2020
Record · missed required monitoringColiform bacteria (Revised Total Coliform Rule)2025

Other systems serving or based in ZIP 21157

SystemEPA PWS IDPeople servedViolations
Freedom DistrictMD006000224,86715
Wakefield ValleyMD00600172,4364
Bark Hill Bible ChurchMD00600191630
Pleasant ValleyMD00600091502
Tebbston On MagothyMD00200595232

On a private well? EPA public-system data does not describe your individual well. Test your water directly.

What the numbers mean

EPA uses two different benchmarks: the legal limit (MCL) and the health goal (MCLG). They are not always the same number. Read EPA's explanation →

Open the interactive report →What the government says

Sources: U.S. EPA SDWIS (system record and violations, queried live) · EPA UCMR 5 final dataset · EPA SDWIS lead & copper 90th-percentile results. EPA data can lag the latest tests.